OPTION 1 - 12- or 24-Hour Clock Format
Press and hold SET for 3 seconds to enter the Option Setting mode.
The first option is 12- or 24-hour clock format. (12:Hr will be flashing)
Press UP or DOWN to toggle between 12- or 24-hour format.
OPTION 2 - Heat Cycle Rate
Press SET again to advance to the second option (Cycle rate. Cr:1 will flash)
Press UP or DOWN button to adjust setting (see cycle rate definition on following pages)
Cr0 = Full Power, No Cycle (for fan-assisted heating devices)
Cr1 = 20 Sec. Proportional Power (for non-fan-assisted baseboards and electric heating devices)
Cr2 = 240 Sec. Proportional Power (for convectors and radiant ceiling)
OPTION 3 - Pre-Comfort Recovery
Press SET again to select pre-comfort recovery. (rE:1 will flash on screen)
Press UP or DOWN to adjust setting (see pre-comfort recovery definition on following pages)
rE:0 means pre-comfort recovery feature is disabled
y feature is enabled
rE:1 means pre-comfort recover